IMPORTANT:

Coil failure due to improper pH level will VOID

THE WARRANTY.

Steam Requirements

Shaded areas are stated in metric equivalents
* The minimum operating pressure is 100 psig (689.47 kPa) for optimum

fresults.

Installation Instructions

To ensure an adequate supply of steam is provided, be sure

that the steam supply lines and steam return lines are sized

and laid out as stipulated in this manual. Inadequate steam

supply lines and steam return lines or improper steam

plumbing will result in poor performance and can cause

component failure. Clean, dry steam must be provided to

the dryer.

IMPORTANT:

Steam coil failure due to water hammer by wet

steam will VOID THE WARRANTY.

The pressure of the condensate in the steam supply line will

cause water hammer and subsequent heat exchanger

(steam coil) failure. The steam supply connection into the

main supply line must be made with a minimum 10-inch

(25.4 cm) riser. This will prevent any condensate from draining

towards the dryer.

The steam supply line to the dryer must include a 12-inch

(30.48 cm) riser along with a drip trap and check valve. This

will prevent any condensate from entering the steam coil.

Flexible hoses or couplings must be used. The dryer vibrates

slightly when it runs and this will cause the steam coil

connections to crack if they are hard piped to the supply and

return mains.

Shutoff valves for each dryer should be installed in the supply

line, return line, and drip trap return line. This will allow the

dryer to be isolated from the supply main and the return main

if the dryer needs maintenance work.

Install an inverted bucket steam trap and check valve at least

12-inches (30.48 cm) below the steam coil as close to the

coil as possible. A trap with a capacity of 150 lbs (68 kg) of

condensate per hour at 125 psi (8.62 bar) is needed for each

unit.

The supply line and the return line should be insulated. This

will save energy and provide for the safety of the operator and

maintenance personnel.

Water pockets in the supply line, caused by low points, will

provide wet steam to the coil possibly causing steam coil

damage. ALL horizontal runs of steam supply piping should

be pitched 1/4-inch (6.35 mm) for every 1 foot (0.31 meters)

back towards the steam supply header causing the

condensate in the line to drain to the header. Install a bypass

trap in any low point to eliminate wet steam.

IMPORTANT:

Flexible hoses/couplings must be used. Coil

failure due to hard plumbing connections will

VOID THE WARRANTY.

!

!

!