GAS INFORMATION

It is your responsibility to have ALL plumbing connections

made by a qualified professional to ensure that the gas

plumbing installation is adequate and conforms with local

and state regulations or codes. In the absence of such codes,

ALL plumbing connections, materials, and workmanship

must conform to the applicable requirements of the National

Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada,

the Canadian Installation Codes CAN/CGA-B149.1-M91

(Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.]

Gas) or LATEST EDITION.

IMPORTANT:

Failure to comply with codes or ordinances, and/

or requirements in this manual, can result in

personal injury and improper operation of the

dryer.

The dryer and its individual shutoff valves must be

disconnected from the gas supply piping system during any

pressure testing of that system at test pressures in excess

of 1/2 psig (3.5 kPa). The dryer must be isolated from the

gas supply piping system by closing its individual manual

shutoff valve during any pressure test of the gas supply

system at test pressures equal to or less than 1/2 psig (3.5

kPa).

IMPORTANT:

Failure to isolate or disconnect the dryer from

supply as noted can cause irreparable damage

to the gas valve, which will VOID THE

WARRANTY.

WARNING:

FIRE OR EXPLOSION COULD RESULT due

to failure of isolating or disconnecting the gas

supply as noted.

Gas Supply

The gas dryer installation must meet the American National

Standard...National Fuel Gas Code ANSI Z223.1-LATEST

EDITION, or in Canada, the Canadian Installation Codes CAN/

CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P.

Gas) or LATEST EDITION, as well as local codes and

ordinances and must be done by a qualified professional.

NOTE:

Undersized gas piping will result in ignition

problems, slow drying, increased use of energy,

and can create a safety hazard.

The dryer must be connected to the type of heat/gas indicated

on the dryer data label. If this information does not agree with

the type of gas available, DO NOT operate the dryer. Contact

the reseller who sold the dryer or contact the ADC factory.

IMPORTANT:

Any burner changes or conversions must be

made by a qualified professional.

The input ratings shown on the dryer data label are for

elevations up to 2,000 feet (609.6 meters), unless elevation

requirements of over 2,000 feet (609.6 meters) were specified

at the time the dryer order was placed with the factory. The

adjustment or conversion of dryers in the field for elevations

over 2,000 feet (609.6 meters) is made by changing each

burner orifice. If this conversion is necessary, contact the

reseller who sold the dryer or contact the ADC factory.

IMPORTANT:

This gas dryer is not provided with an internal

gas supply shutoff and an external gas supply

shutoff must be provided.

Technical Gas Data

Gas Specifications

Shaded areas are stated in metric equivalents

* Measured at outlet side of gas valve pressure tap when the gas valve is on.

Gas Connections

Inlet connection

1/2” N.P.T.

Inlet supply size

1/2” pipe (minimum)

Btu/hr input 50,000 (12,600 kcal/hr)

Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal

regulator. Incoming supply pressure must be consistent

between a minimum of 6.0 inches (14.92 mb) and a

maximum of 12.0 inches (29.9 mb) water column (W.C.)

pressure.

Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s

internal pressure regulator blocked open so that the gas

pressure must be regulated upstream of the dryer. The

pressure measured at each gas valve pressure tap must

be a consistent 10.5 inches (26.1 mb) water column.

There is no regulator or regulation provided in an L.P.

dryer. The water column pressure must be regulated at

the source (L.P. tank) or an external regulator must be

added to each dryer.

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#41 = 0.0960” (2.4384 mm).

Liquid Propane Gas

#54 = 0.0550” (1.397 mm).

Piping Connections

ALL components/materials must conform to National Fuel

Gas Code Specifications ANSI Z223.1-LATEST EDITION, or

in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/

CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST

EDITION (for General Installation and Gas Plumbing), as well

as local codes and ordinances and must be done by a

qualified professional. It is important that gas pressure

regulators meet applicable pressure requirements, and that

gas meters be rated for the total amount of ALL the appliance

Btus being supplied.

7<3( 2) *$6

Gv„ˆvq

Q…‚ƒhr

8‚‰r…†v‚ÃFv‡

Qh…‡ÃIˆ€ir…

7‡ˆu…

Sh‡vt

NFDOKU

UDWLQJ

Ih‡ˆ…hy

Gv„ˆvqÃQ…‚ƒhr

R‡’ 9HT Qh…‡ÃI‚ R‡’ 9HT Qh…‡ГI‚

$

!

Ж#

#'

!

Ж$#

#'#'

'&#$

7<3( 2) *$6

I6UVS6G

GDRVD9ÃQSPQ6I@

ÃÃHhvs‚yqÃQ…r††ˆ…r

"$Ãvpur†ÃX8

'&Ài

$Ãvpur†ГX8 !% Г€i

ÃÃDGvrÃQ…r††ˆ…r

%ГГ !Гvpur†ГX8 #(!ГГ!((Г€i Ãvpur†ÃX8 !&#Ài

!

!

!

!

!