PREOPERATIONAL INSTRUCTIONS

Coin Models

Microprocessor Controller (Computer)

When the microprocessor controller (computer) is in the

ready state, the liquid crystal display (L.C.D.) screen will

display “Ready, Insert $XX.XX (amount) to Start”.

Insert coin(s). Once the correct “Amount to Start” has

been inserted, the L.C.D. will display “Select

Temperature”.

Select temperature by pressing “HI,” “MED,” or “LO.” The

cycle will start and the L.C.D. will display the Dry Cycle

selected and the remaining time.

The dryer will continue through the drying and cooling

cycles, until the vended time has expired.

NOTE:

To stop dryer, open main door or pressing the

pause key. Continuation of the cycle will

resume only after the door has been closed and

any of the three (3) temperature selection is

pressed.

Upon completion of the drying and cooling cycles, the

tone (buzzer) will sound and the dryer will go into the

Anti-Wrinkle Mode for 99 minutes, or until the main door

has been opened.

IMPORTANT:

For more detailed information regarding the

microprocessor controller (computer) on your

dryer, refer to the microprocessor user’s manual

included with the dryer.

Gas Models Only

When a gas dryer is first started (during initial start-up),

it has a tendency not to ignite on the first ignition attempt.

This is because the gas supply piping is filled with air,

so it may take a few minutes for the air to be purged from

the lines.

NOTE:

During the purging period, check to be sure that

ALL gas shutoff valves are open.

Gas model dryers are equipped with an ignition

system, which has internal diagnostics. If

ignition is not established after one (1) time,

the heat circuit in the ignition module will attempt

two (2) more ignitions (total of three [3] ignition

attempts). If there is no flame after the third

ignition attempt the module will lock out until it

is manually reset. To reset the ignition system,

open and close the main door and restart the

dryer.

A gas pressure test should be taken at the gas valve

pressure tap of each dryer to ensure that the water

column (W.C.) pressure is correct and consistent.

NOTE:

Water column pressure requirements

(measured at the pressure tap of the gas valve

body):

Natural Gas .............................3.5 Inches (8.7 mb) W.C.

Liquid Propane (L.P.) Gas ......10.5 Inches (26.1 mb) W.C.

IMPORTANT:

There is no regulator provided in an L.P. dryer.

The water column pressure must be regulated

at the source (L.P. tank), or an external regulator

must be added to each dryer.

Make a complete operational check of ALL safety related

circuits:

•

Door Switch(es)

•

Hi-Limit Thermostats

•

Cycling Thermostat

•

GAS AND ELECTRIC MODELS ONLY - Sail Switch

NOTE:

The sail switch can be checked for proper

operation by opening the lint door while heating

circuit (gas burner/electric oven) is active (on).

The heating unit should shut off within a few

seconds. If not, make necessary adjustments

to the sail switch.

Make a complete operational check of ALL operating controls.

NOTE:

If computer program changes are required, refer

to the computer programming section of the

manual supplied with the dryer.

The dryer should be operated through one (1) complete cycle

to ensure that no further adjustments are necessary and that

ALL components are functioning properly.

BASKET (TUMBLER) COATING

The basket (tumbler) is treated with a protective coating.

We suggest dampening old garments or cloth material

with a solution of water and nonflammable mild detergent

and tumbling them in the basket (tumbler) to remove

this coating.

Check the electric service phase sequence (3-phase [3ø]

models only). While the dryer is operating, check to see if the

blower wheel (impellor/fan) is rotating in the proper direction.

Looking from the front, the blower wheel (impellor/fan) should

spin in the clockwise (CW) direction. If it is, the phasing is

correct. If the phasing is incorrect, reverse two (2) of the three

(3) leads at connections L1, L2, and L3 of the power supply

to the dryer.

IMPORTANT:

If the blower wheel (impellor/fan) is rotating in

the wrong direction, this will not only drastically

reduce drying efficiency, but it can also cause

premature component failure.

!

!

!

!

!

!

!

!