For Models with Johnson Direct Spark Ignition (DSI) Controller

(G760)

Theory of Operation:

Start the drying cycle. When the gas burner ignites within the

chosen trial for ignition time (6-seconds), the flame sensor

detects gas burner flame and signals the DSI module to

keep the gas valve open as long as there is a call for heat.

The DSI module will “LOCK OUT” if the gas burner flame is

not sensed at the end of the trial for ignition period. The trial

for ignition period will be repeated for a total of three (3) retries/

trials (the initial try and two [2] more retries/trials). If the flame

is not sensed at the end of the third retry/trial (inter-purge

period of 30-seconds) the DSI module will “LOCK OUT” (light

emitting diode [L.E.D.] diagnostic indicator flashes).

A steady L.E.D. indicator indicates normal operation.

No L.E.D. indicator indicates a power or an internal failure

has occurred.

For Models with Fenwal Controls DSI Module (128937)

Theory of Operation:

Start the drying cycle. When the gas burner ignites within the

chosen trial for ignition time (8-seconds), the flame sensor

detects gas burner flame and signals the DSI module to

keep the gas valve open as long as there is a call for heat.

The DSI module will “LOCK OUT” if the gas burner flame is

not sensed at the end of the trial for ignition period. The trial

for ignition period will be repeated for a total of three (3) retries/

trials (the initial try and two [2] more retries/trials). If the flame

is not sensed at the end of the third retry/trial (inter-purge

period of 30-seconds), the DSI module will “LOCK OUT” (a

red L.E.D. diagnostic indicator will flash).

An unlit red L.E.D. diagnostic indicator indicates normal

operation.

A lit green L.E.D. diagnostic indicator indicates dryer controller

is calling for heat and that ALL interlocks have been satisfied.