Brother MW-260 User Manual
Page 71
49
ESC iXR1
Retrieve line return command setting text string
[ASCII]
ESC i X R 1 n1 n2
[Decimal]
27 105 88 82 49 nd1 nd2
[Hexadecimal]
1B 69 58 52 31 nh1 nh2
[Parameters]
nh1:00h
(Fixed)
nh2:00h
(Fixed)
[Description]
·
Retrieves the text string specified for the line return command.
·
2- to 22-byte data is returned from the machine. (Varies depending on the length of the
text string)
[1, 2]: nh1 nh2 (number of characters) nh1 + (nh2*256)
[3 and later]: Text string
·
The retrieved value is a value specified by a static command.
[Example]
·
When the text string for the line return command is specified as “0Dh 0Ah”:
If ESC i X R 1 00h 00h (1Bh 69h 58h 52h 31h 00h 00h) is sent to the machine, 02h 00h
0Dh 0Ah is returned from the machine.