Esc ixi1 retrieve command mode setting – Brother MW-260 User Manual
Page 66
44
ESC iXi1
Retrieve command mode setting
[ASCII]
ESC i X i 1 n1 n2
[Decimal]
27 105 88 105 49 nd1 nd2
[Hexadecimal]
1B 69 58 69 31 nh1 nh2
[Parameters]
nh1:00h (Fixed)
nh2:00h (Fixed)
[Description]
·
Retrieves the setting for the command mode.
·
3-byte data is returned from the machine.
[1]:01h (Fixed)
[2]:00h (Fixed)
[3]: Setting
00h:
ESC/P mode
01h:
Raster mode
03h:
P-touch Template mode
·
The retrieved value is a value specified by a static command.
[Example]
When the setting is for raster mode:
ESC i X i 1 00h 00h
(1Bh 69h 58h 69h 31h 00h 00h)
The following is returned from the machine.
01h 00h 01h