Brother MW-260 User Manual
Page 16
16
CODABAR: 4 to 64 characters (with “A”, “B”, “C” or “D” at the beginning and end)
CODE128: 1 to 64 characters
GS1-128 (UCC/EAN-128): 1 to 64 characters
When trying to transfer data exceeding the ranges describe above, an error will occur
while transferring. If the data that is fed does not meet the minimum limit, the bar code is
not printed. If the data exceeds the maximum limit, only the data to the maximum limit is
applied. However, if the data exceeds 64 characters, the bar code is not printed.
·
If a template is created in P-touch Editor with an extremely low bar code bar height, the
bars may not be printed.
●CODE39
·
When feeding data, the asterisks (*) at the beginning and end of the data are skipped.
●I-2/5
·
The bearer bar setting specified in P-touch Editor is invalid.
●GS1-128 (UCC/EAN-128)/CODE128
·
If the bar code width has been set to “Minimum” in P-touch Editor, the characters below the
bar code are not printed, even if the “Show Characters” setting has been selected.
●QR Code
·
The version setting for a QR Code specified in P-touch Editor is invalid. The version setting
must be turned off.
·
The joining setting specified in P-touch Editor is invalid.
●
PDF417
·
Since the error correction levels for PDF417 specified in P-touch Editor are inconsistent
with those on the
printer
, the size of the bar code may change when it is printed with
P-touch Template.
·
The width for PDF417 specified in P-touch Editor may change from “Minimum” to “Small”.
·
The joining setting specified in P-touch Editor is invalid.
●
DataMatrix
·
The joining setting specified in P-touch Editor is invalid.
·
Macro settings specified in P-touch Editor are invalid.
■ Relating to images
·
If a template containing overlapping images is transferred with P-touch Editor, all image
data will be overlapping. (P-touch Editor displays the image created last on top.)