TROUBLESHOOTING

SECTION 7-4

Electrical Faults

PROBLEM

Electrical Faults

PROBABLE CAUSE

REMEDY

A. Motor fails to start

1. Power supply failure.

1. Check fuses.

2. Starter is inoperative.

2. Check supply mains. Also,

check starter contacts for burning,

replace if necessary.

3. Starter overloads cut out.

3. Check current requirements on

motor nameplate and adjust.

4. Safety interlock is inoperative. 4. Check and adjust as needed.

B. Motor starts, but will not take

load.

1. Too much belt tension.

1. Check belt tension and adjust

as necessary. Refer to section 4.

2. Motor is improperly wired.

2. Check terminal connection

with manufacturers connection

diagram in conduit box and adjust

as necessary.

3. Defective starter winding.

3. Check current in each phase

with an ammeter. If there is

marked difference in current on

any phase, contact the motor

manufacturer.

C. Motor starts when

disconnected from load, but will

not when connected.

1. Worn bearings.

1. Check and replace if necessary,

in accordance with manufacturers

literature.

1.