OPERATION

SECTION 5-4

Safely Clearing a Jam

TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-1982

(Lockout/Tag out of Energy Sources).

If it is not possible to lock out the power, have an electrician remove the fuses.

Make sure the rotor has come to a complete stop.

Wear gloves to protect against injury from the rotor or bed knives.

OPEN THE CUTTING CHAMBER

Open the screen cradle per instructions in Section 6-4 entitled Screen Replacement.

Open the cutting chamber per instructions in Section 6-9 entitled Cutting Chamber

Access.

NEVER ATTEMPT TO FREE A JAMMED MACHINE BY PLACING YOUR HANDS ON
THE ROTOR, ON THE KNIVES, OR INSIDE THE CUTTING CHAMBER.

KEEP YOUR HANDS CLEAR OF THE ROTATIONAL PATH OF THE ROTOR KNIVES.