beautypg.com

Maintenance – Sterlco ST500 Series Central Granulator User Manual

Page 69

background image

69

MAINTENANCE

SECTION 6-4

Screen Replacement

TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-1982

(Lockout/Tag out of Energy Sources).

If it is not possible to lock out the power, have an electrician remove the fuses

Make sure the rotor has come to a complete stop

Wear gloves to protect against injury from the rotor or bed knives

OPEN THE CUTTING CHAMBER SAFETY INTERLOCK

Disengage the interlock actuator screws
Back the screws out as far as they will go. When unscrewed, the interlock will still be

captive on the door to prevent loss.

When disengaged, the interlock opens the electrical control circuit to the motor and

prevents the machine from running.

Remove the granulate deflector and set aside