beautypg.com

Settings and adjustments – Sterlco ST500 Series Central Granulator User Manual

Page 43

background image

43

SETTINGS AND ADJUSTMENTS

SECTION 4-9

Adjusting or Replacing Bed Knives

FASTEN THE SCREEN CRADLE

Raise the cradles to their upright positions one at

a time.

Tighten the bolts until they are tight against the

chamber housing.

Final Torque

CLOSE THE CUTTING CHAMBER SAFETY
INTERLOCK

Engage the safety interlock by turning the

actuator screw clockwise until tight

Make sure the screw is fully seated

When engaged, the interlock closes the electrical

control circuit to the motor and allows the machine to

run.

RESTART THE GRANULATOR

If necessary to replace the fuses, call an electrician to do it.

UNLOCK AND TURN ON the main power.

Remove the OUT OF SERVICE tag.

Start the granulator by depressing the start pushbutton on the electrical cabinet.