Settings and adjustments – Sterlco ST500 Series Central Granulator User Manual
Page 43

43
SETTINGS AND ADJUSTMENTS
SECTION 4-9
Adjusting or Replacing Bed Knives
FASTEN THE SCREEN CRADLE
Raise the cradles to their upright positions one at
a time.
Tighten the bolts until they are tight against the
chamber housing.
Final Torque
CLOSE THE CUTTING CHAMBER SAFETY
INTERLOCK
Engage the safety interlock by turning the
actuator screw clockwise until tight
Make sure the screw is fully seated
When engaged, the interlock closes the electrical
control circuit to the motor and allows the machine to
run.
RESTART THE GRANULATOR
If necessary to replace the fuses, call an electrician to do it.
UNLOCK AND TURN ON the main power.
Remove the OUT OF SERVICE tag.
Start the granulator by depressing the start pushbutton on the electrical cabinet.