beautypg.com

Rear chamber access, Maintenance – Sterlco ST500 Series Central Granulator User Manual

Page 74

background image

74

MAINTENANCE

SECTION 6-9

Cutting Chamber Access

REAR CHAMBER ACCESS

RELEASE THE CUTTING CHAMBER

FASTENERS

Release the safety switch actuator screw with a box

wrench.

Loosen the hold-down clamp bolts to allow the plates

to slide upward to release the rear hatch.

Once the hold-down clamps are out of the way tighten

one of the bolts to keep them up.

The pneumatics, which open the machine, should not operate

until the power is completely disconnected. If you discover

that the pneumatics DO operate while the power is still on,

immediately shut down the machine and call for maintenance

to adjust it.

Make sure no one is near the rear hatch during

operation.

Actuate the cutting chamber cylinder from the

pneumatic console by turning the switch to the

LOWER position. Hold the switch till the hatch stops