beautypg.com

Settings and adjustments – Sterlco ST500 Series Central Granulator User Manual

Page 35

background image

35

SETTINGS AND ADJUSTMENTS

SECTION 4-1

Adjusting or Replacing Bed Knives

BASIC FACTS ABOUT THE KNIVES

All of the rotor knives are ground in sets to equal dimensions. Mount and service them as sets.

The rotor knives must be mounted tightly against the backs of the knife seats, in order to make it

possible to achieve consistent knife clearances.

Accurate cutting clearance is obtained by setting the bed knives to a 0.006 in. to 0.008 in. (0.15

mm to 0.20 mm) gap from the rotor knives.

The bed knives are adjusted by turning captive adjusting screws. For best results, start with the bed

knives adjusted to a wide gap from the rotor knife, and slowly adjust them

to the required gap by

turning the screws in the same direction; avoid reversals. Reversals introduce inaccuracies due to
backlash.

CHECK ALL SETTINGS AND ADJUSTMENTS BEFORE GRANULATING ANY

MATERIAL

Proper adjustments and settings are made prior to shipment; however the machine may require
readjustment. The standard knife gap setting is between six and eight thousandths of an inch (0.006 in. to
0.008 in. or 0.15 mm to 0.20 mm).

NOTE: These instructions apply to both the upstroke (the bed knife when you access the front of the
machine) and the down-stroke bed knives (the bed knife when you access the rear of the machine).

A malfunction of the machine, such as a jam, may cause undue strain or damage to any part. Do not restart
the machine after such a malfunction without checking to see whether damage was done or whether settings
were changed by the malfunction.



TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-1982 (Lockout/Tag-out of
Energy Sources).
If it is not possible to lock out the power, have an electrician remove the fuses. Make sure the rotor has
come to a complete stop.