beautypg.com

Installation – Sterlco ST500 Series Central Granulator User Manual

Page 28

background image

28

INSTALLATION

SECTION 3-2

Moving and Leveling the Granulator

MOVE THE GRANULATOR TO ITS WORK SITE

If lifting the machine is necessary, use appropriately rated lifting equipment. Always lift the unit

from beneath the base plate.

The machine weights for the A

T500 Series Granulators are as follows: ST5070 10000 pounds

ST5090 12500 pounds

ST50120 16000 pounds

ALLOW ADEQUATE WORK SPACE

Adequate clearance must be maintained so that all areas of the granulator are accessible and

unobstructed for servicing, maintaining, or operating the equipment. Space must be allowed for

removing guards and screens.

Allow 3 feet (915 mm), 4 feet (1220 mm), and 4.5 feet (1321 mm) on the front and back of the

machine for access; models ST5070, ST5090, ST50120 respectively.

LEVEL THE GRANULATOR

Once the granulator is at its final installation site, ensure that the machine is on a level surface and

resting firmly on its base plate. If necessary, use shims to level it.

It can be mounted on isolation pads or it can be lagged to the floor through holes provided in the

base plate.

TURN OFF AND LOCKOUT the power per OSHA 1910.147 OR ANSI Z244.1-1982

(Lockout/Tag-out of Energy Sources).
If it is not possible to lock out the power, have an electrician remove the fuses. Make sure the

rotor has come to a complete stop.
(Continued on next page)