CLOSE THE CUTTING CHAMBER WITH

PNEUMATICS

Actuate the cutting chamber cylinder from the

pneumatic console by flipping the switch to the RAISE

position. Hold until hatch is fully closed.

Make sure hold-down clamps are up out of the way and

then lower over the hatch once it is closed.

Tighten hold-down clamps and reset the safety switch

actuator bolt

MAINTENANCE

SECTION 6-10

Cutting Chamber Access

CLOSE THE SCREEN CRADLE INTERLOCK

Engage the interlock screw by turning it clockwise with a

box wrench or a ratchet wrench.

Make sure the interlock actuator screw is fully seated

against the top surface of its housing.

When engaged, the interlock switch closes the electrical control

circuit to the machine and allows it to operate.

CLOSE THE CUTTING CHAMBER SAFETY
INTERLOCK

Engage the safety interlock by turning the

actuator screw clockwise until tight

Make sure the screw is fully seated

When engaged, the interlock closes the electrical

control circuit to the motor and allows the machine to

run.