Digital Dosing Units

9




Recipe Setup for Injection Molding:

1. Turn power switch to ON position.

2. Press Input

to display # 1, “Additive %”. Using arrow keys, set additive ratio.

3. Press Input

to display #2, “Shot size of current mold”. Using arrow keys, set the

total shot size (parts and runners) of the current mold capacity in grams/pounds.

4. Press Input

to display # 3, “Screw recovery time”. Using arrow keys, set the

screw recovery time (in seconds).

5. Press Input to display # 4, “Calibration weight for additive”. Enter the appropriate

value from the range table below and proceed to calibration mode below for calibration

of additive material.

DD Discs

Disc Calibration

Number

Range

DD 30-030672 1.75

DD 30-051040 5.00

DD 30-051725 8.00

DD 30-051818 15.00

DT Discs

DP Discs









Disc Calibration

Number

Range

DT 30-101820 32.00

DT 30-102025 38.00

DT 30-203012 100.00

DT 30-204010 175.00

Disc Calibration

Number

Range

DP 30-050940 17.00

DP 30-250940 8.00