background image

Digital Dosing Units

39

This sample should be returned to the material hopper without weighing.

This sample is used only to ensure that all disc pockets are completely filled.

• Replace container in calibration box (or under material outlet tube)

Step 3:

• Press

to take a sample for weighing.

• The disc will rotate one full revolution. After the disc has stopped rotating, a

number in the format “xx.xx” will appear on the screen along with a flashing

and “g.”

Step 4:

• Enter the weight, in grams using the Arrow Keys

• Empty and replace weighing container in calibration box (or under material

outlet tube)

Step 5:

• Repeat steps 3 and 4 four (4) more times.
• Notice that the displayed calibration weight may change after each sample

weight is entered.

The value is an average of all the weights entered. No calculations are

required.

It can happen that the calculated speed is either too high or low

causing alarm A0009. Check the recipe and settings and modify if

necessary.