beautypg.com

Sterlco S-150 Digital Dosing Controller User Manual

Page 25

background image

Digital Dosing Units

25

Step 2:

• Press Input

again.

• The symbols “g,” or “lb”, “min” and the screw symbol flash.
• After the “2”quickly flashes on the display, a number in the format xx.xxx will

come up on the display.

• Enter the shot weight using the arrow keys. The range of values that can be

entered is 001.0 to 6500 grams (0.01 to 14.30 pounds).

Step 3:

“3” = screw recovery time in seconds

• Press

Input

a third time.

• The

screw

and “s” symbols flash.

• After “3” flashes quickly on the display, a number in the format xxx.xx will come

up on the display.

• Enter the screw recovery time in seconds. This time represents the amount of

time the molding machine screw is in recovery. This value is an estimate.

The Digital Dosing unit measures the actual recovery time and automatically

updates this value during operation. NOTE: The range of values that can be

entered in this field is 2.00 to 99.99 seconds.