Digital Dosing Units

35

• After “2” flashes quickly on the display, a number in the format xxx.xx will come

up on the display.

• Enter the expected extruder throughput during production in grams per minute

or pounds per minute. The range of values that can be entered is 001.0 to

6500 grams per minute (00.01 to 14.30 lb/m).

Step 3:

• Press

a third time.

• The machine displays a flashing screw

.

• After “3” flashes quickly on the display, a number in the format xxx.xx will come

up on the display.

• Enter the extruder screw speed (rpm) corresponding to the throughput entered

in step 2.


Step 4:

“ 4 “ = calibration weight in grams or pounds

• Press

a fourth time.

• The machine displays a flashing and “g”.
• After “4” flashes quickly on the screen, a number in the format xxx.xx will come up

on the display.

• Enter the calibration weight in grams. If the calibration weight is unknown,

enter the appropriate “value” from Section 2, based on your disc size, to

obtain a starting weight.

Upon completion of the calibration procedure, the calibration weight will

automatically be updated into the recipe

. The range of values that can be

entered in this field is 00.00 to 400.0.