background image

Digital Dosing Units

58

Appendix B: Basic Parameter Settings


Extrusion Mode:
You need an extruder signal that is proportional to the extruder speed to operate in the

Extrusion - Proportional mode. You can use any of the following:

• Frequency signal (must be 12 VDC square wave)
• 0 - 10 VDC signal
• 0 - 20 mA current signal

Determine the frequency output in the lower working area (A) of the extruder. Record the

data. Min. input frequency = __________ Hz

Determine the frequency output in the upper working area (B) of the extruder. Record the

data.


Max. input frequency = __________ Hz

If a voltage signal is available (0 - 10 VDC) calculate the frequency output of the extruder for

the lower / upper working area using the formula:

Frequency [Hz] = Input voltage [V] x 10000 [Hz]

10 [V]

Note the data:
Min. input frequency = __________ Hz
Max. input frequency = __________ Hz

If a current signal is available (0 - 20 mA) calculate the frequency output of the extruder for

the lower / upper working area using the formula: