Digital Dosing Units

22

J12-4

_




J12-3

+



0-10 VDC or 0-20 mA

Extruder output

Digital Dosing controller

(diagram of analog inputs)

Figure 6. Analog Inputs

5. Make sure the unit is turned OFF before plugging it in. The switch toward the rear of

the controller unit should be in the OFF, or “O” position. Standard operation voltage is

110 or 220 VAC, 50/60 Hz, single-phase power. Special voltages are available, refer

to voltage label on the feeder to determine the correct operating voltage.

Extruder Follower Interface Signal Converter

Isolating power sources and sensor signals is the most effective method for eliminating

undesirable ground loop currents and induced electrical noise.

To determine the correct signal convert to use:

o

Define whether a current (mA) or voltage (dc) signal from the extruder is

available to utilize.

o

The range should be either be 0-20 mA or 0-10 VDC, respectively.

o

The controller has no specific requirement other than the signal being isolated

and proportional to the speed of the extruder.

Signal Converter with AC Power Supply

Vendor:

Phoenix Contact

Order Designation: MCR-FL-C-UI-UI-DCI-24/230

Supply Voltage:

20V to 253V AC/DC

Input 4-20 mA, 0-10 VDC (Quantity: 1)

Output 0-20 mA, 0-10 VDC (Quantity: 1)