PNI Legacy Comm Board User Manual
Page 27
PNI Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403-1084 USA;, Fax: (707) 566-2261
For the most current specifications, please visit our website at:
www.pnicorp.com
Page 27 of 42
ps (ASIC Period Select)
Sets the value for the ASIC period select. The lowest setting (/32) will provide the fastest
response, but the lowest resolution. The highest setting will provide the slowest response, but the
highest resolution. Refer to specific module data sheet for more response times and maximum
setting allowed.
Syntax:
ps
Response Format:
$ps=n*
Syntax: n
=
=0
=/32
=1
=/64
=2
=/128
=3
=/256
=4
=/512
(default)
=5
=/1024
=6
=/2048
=7
=/4096
Query Syntax:
ps?
save (Save Settings)
Saves the configuration parameters to the CommBoard and attached module (where applicable).
Also used to save calibration coefficients to the CommBoard and attached module (where
applicable)
Syntax:
save
Response Format:
$save*
CommBoard