PNI Legacy Comm Board User Manual
Page 16

PNI Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403-1084 USA;, Fax: (707) 566-2261 
For the most current specifications, please visit our website at: 
www.pnicorp.com
Page 16 of 42
s? (Single Sample Update)
Retrieves the user selected calibration information. Based upon the settings of the various 
Configuration commands 
 
Note: For modules that do not have an onboard processor (for example, the MicroMag), the 
CommBoard will calculate and output this data 
 
Syntax: 
s?
Response Format:
${selectedData}*
 
Valid Values: 
selectedData
varies according to user settings
 
 
sr? (Single Raw Sample Update)
Retrieves the raw data (uncorrected ASIC output) for the sensors selected. For example, X, Y, 
and Z axis magnetometers. The Z sensor output is not available on all modules. Refer to the spe-
cific module data sheet for more information 
Syntax:
sr?
Response Format:
${selectedRawData}*
 
Valid Values: 
selectedRawData
varies according to user settings
 
 
t? (Temperature Update)
Retrieves the temperature value. Outputs are based on the setting of the Temperature Units (ut) 
command. The temperature output is not available in all modules. Refer to the specific data sheet 
for more information. 
 
Syntax:
t?
Response Format:
$Tn.n*
 
Valid Values: 
$Tn.n
the calibrated temperature sensor output
 
 
 
 
CommBoard
Query Commands