PNI Legacy Comm Board User Manual
Page 21
PNI Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403-1084 USA;, Fax: (707) 566-2261
For the most current specifications, please visit our website at:
www.pnicorp.com
Page 21 of 42
ez (Z Axis Data Enable)
Enables the Z-axis data output. The Z sensor output is not available on all modules. Refer to the
specific module data sheet for more information. Z-axis is only active in raw mode.
Syntax:
ez
Response Format:
$ez={value}*
Valid Values:
e =
enabled
d =
disabled (default)
Query Syntax:
ez?
halt (Single Character Halt Enable)
Enables sending a single Halt (h) command to cancel the Continous Output (go) mode.
Syntax: halt
Response Format:
$halt={value}*
Valid Values:
e
enabled; h (default)
d disabled;
h
Query Syntax:
halt?
lpm (Low Power Mode)
Selects the low power mode for the CommBoard. Once set to
lpm=2
, the CommBoard will
“wake” from ultra low power and go into
lpm=0
when it receives a character over the RS-232
on page 4 lists the current draw at the different lpm levels.
Syntax:
lpm
Response Format:
$lpm={value}*
Valid Values:
0
no conversion (default)
1
LEDs off
2
ultra low power
Query Syntax:
lpm?
CommBoard
Configuration Commands