echo (Echo Characters Enable)

Enables character echo, which directs the CommBoard to echo locally typed characters onto the
display

Syntax: echo

Response Format:

$echo={value}*


Valid Values:

e =

enabled

d =

disabled (default)


Query Syntax:

echo?


em (Magnetometer Data Enable)

Enables all of the magnetometer data output. For example,

em=e

will set

ex=e

,

ey=e

and

ez=e

.


Note: If any axis is disabled after

em=e

,

em?

will still respond with

em=e

. Z-axis is only active

in raw mode.

Syntax: em

Response Format:

$em={value}*


Valid Values:

e =

enabled

d =

disabled (default)


Query Syntax:

em?


eol (End of Line Enable)

Sets the type of end of line output

Syntax: eol

Response Format:

$eol={value}*


Valid Values:

cr =

output cr after line

lr =

output lr after line

crlf = output crlf after line (default)


Query Syntax:

eol

?