Prime User Manual r08

Page 15

takes more time. If this checkbox is deselected, then the module will NOT wait for a

stable reading and will immediately take a reading once the minimum change-

between-points threshold has been met.

Automatic Sampling

When this checkbox is selected, the module automatically takes a calibration point

once the minimum change-between-points requirement and the stability check

requirement (if selected) have been satisfied. If the user wants direct control over

when a calibration point is taken, then Automatic Sampling should be deselected. In

this case, the button on the Calibration tab will be active. Clicking

the button indicates to the module to take a sample once the

minimum requirements are met.

Calibration Points

The user can select the number of points to take during a calibration. A minimum of

12 sample points are needed for a successful magnetic sensor calibration, while 18

samples are recommended for either accelerometer-only calibration or simultaneous

magnetic sensor and accelerometer calibration.

Mag Only Calibration

Select when only magnetic sensor calibration will be performed.

Accel Only Calibration

Select when only an accelerometer calibration will be performed.

Accel and Mag Calibration

Select when magnetic sensor and accelerometer calibrations will be performed

simultaneously.

5.3.7

Default

Clicking this button reverts the StudioPrime program to the factory default settings.

5.3.8

Revert

This button will have the StudioPrime program read the settings from the unit and display

them on the screen.

5.3.9

Enable 3D Model

StudioPrime’s Test tab includes a live-action 3-D rendering of a helicopter. Some
computer systems may not have the graphics capability to render the 3D Model, and for

this reason it may be desirable to turn off this feature.