DEVICE

SAFE C1

Safety controller for e-stop

APPLICATIONS

and gate monitoring applications

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

4 safety semiconductor outputs

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

Wearless contacts, "AND", "OR" functions between several SAFE C1

Automatic start possible

LED

Power, channel 1 and channel 2 + flashing code

24 V DC ( + 25 - 20 % )

OPERATING VOLTAGE

Overvoltage protection

POWER CONSUMPTION

ca. 3 W

START UP DELAY / FALLBACK TIME

< 70 ms / < 30 ms

CONTACT CAPACITY max.

total current 1,8 A

CONTACT CAPACITY min. at 24V DC (*)

infinite

SIMULTANEITY

no (special variants possible)

ENVIRONMENTAL TEMPERATURE

-25°C to + 55°C

SWITCHING CAPACITY

up to 43 W

CONTACT SECURITY

short circuit proof

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

2-channel e-stop application with monitoring of reset circuit, opposite

channels polarity and contact expansion.

The release button must be attached to the e-stop circuits (S11/S12,

S21/S22) and the start button must be attached to the reset-circuit (S34/A1).

The activation of the semiconductor safety outputs takes place after closing

of the reset circuit (pressing the start button).

By linkage more SAFE C1 with one another safety applications also

complicated, with which different components are to be differently

supervised, can be realized.

For monitoring of the external contactor, the NC contacts of the force guided

contactors must be attached in series to the reset circuit.

A1 + 24 V DC

A2 0 V DC

S35

S34

S22 S12 S11

S21

S32

S33

S36 S37

14

34

K1

K2

A2

K1

K2

K1

K2

Not-Halt

E-Stop

Start

FUNCTION CIRCUIT DIAGRAM

A1 A2

Power

Input circuits

S12 S22 S34 S35 S36

Output

circuits

Combination

circuit

S11 S21

S33

MCU1

MCU2

Sa

fe

ty

ou

tp

ut

ci

rc

uit

s

14

24

34

44

S32

S37

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1/ EN 61508: PLe, Cat. 4 / SIL3

MTTFd: 163 years / high, DC: high, CCF: achieved

PFH: 2,87*10

-9 1

/

h

, PFD: 2,01*10

-6 1

/

h,

SFF: 0,9573

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com