DEVICE

SAFE Z

Two hand control relay

APPLICATIONS

for type I-III c

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

2 normally open safety, 1 normally auxiliary closed

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

Two hand control relay according ZH 1 / 456 and DIN EN 574

LED

Power, channel 1 and channel 2

OPERATING VOLTAGE

24 V DC (electronic fuse)

POWER CONSUMPTION

ca. 3 VA

START UP DELAY / FALLBACK TIME

< 50 ms / < 30 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

CONTACT CAPACITY min. at 24V DC (*)

1 mA

SIMULTANEITY

Simultaneous: 0,5 s

ENVIRONMENTAL TEMPERATURE

- 25 °C to + 55 °C

SWITCHING CAPACITY

1500 VA (resistive load)

CONTACT SECURITY

6 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

After supply voltage was applied to terminals A1 and A2, the SAFE Z.2 will

be ready for operation. The power LED illuminates. If the button S1 is

pressed and within 0,5 sec. the button S2 is also pressed, the outputs 13-

14, 23-24 are closed and 31-32 will be opened. The machine will be

started. If one or both buttons are released, the outputs 13-14 and 23-24

open immediately.The output 31-32 closes. Only after releasing the both

buttons S1 and S2, a new cycle can be started. If the time for pressing the

buttons S1 and S2 will be longer as 0,5 sec., the outputs were not released.

The outputs 13-14 and 23-24 keep open. The machine cannot be started.

On the terminals Y1 and Y2 machine release circuits (repeating contactor

control) can be connected.

S11

A2

S21

S1

S22

Y2

S2

FUNCTION CIRCUIT DIAGRAM

S21

Überwachungslogik

K1

fuse

+

-

DC

AC

electr.

elektr.

Sicherung

A1

A2

control logik

S22

S11

14 24

K2

32

Y2

13 23

31

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 36,85 years / high, DC: 99% / high,

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com