Technical data – NORSTAT Safety Relays User Manual
Page 37
22
Technical data
►
Voltage range
SAFE 1/1.1 / SAFE 2/2.1/2.2 / SAFE S.6 / SAFE 4/4.1 / SAFE M
0,9 to 1,1 UB
RS-NAGV / RS-NAGT/T.1 / SAFE L/L.1 / SAFE L.2 / SAFE Z / SAFE IRZ.2
RS-NAGU.12 / RS-NAGU.1 / RS-NAGU.2f
RS-NAGMP/P.1 / RS-NAGA/AO
0,85 to 1,1 UB
SAFE IL1 / SAFE 5/5.1 / RS-NAGL/L.1 / SAFE ILL / SAFE Z.2 / RS-NAGZ / SAFE ILZ
SAFE X4/4.1 / RS-NAGX5 / SAFE IL2 / FI1
SAFE C1, CL, CM, CZ, SAFE TU/ TA/ TN/ TR/ TON, SAFE FLEX, FLEX T, SAFE SM
0,8 to 1,25 UB
FA1 over
ASI-Bus
►
Clearance and creeping distance
DIN EN 50178, or DIN VDE 0160 at pollution grade 2, over voltage category 3/300V
► max. switching voltage
SAFE IL2 :
12 A AC, cos φ = 1
RS-NAGMP/MP.1 :
8 A AC, cos φ = 1; 8 A DC, τ =0
SAFE IRZ.2, SAFE 1/ 1.1/ 4/ 4.1/ M:
5 A AC, cos φ = 1; 5 A DC, τ =0
SAFE IL1, SAFE IL L, SAFE IL Z, RS-NAGV:
4 A AC, cos φ = 1; 4 A DC, τ =0
RS-NAGU.2f:
6 A DC (1 Kontakt), τ = 0
RS-NAGU.1/RS-NAGU.12:
1,5 A DC (1 Kontakt), τ = 0
SAFE C1, SAFE CL, SAFE CM, SAFE CZ:
1,8 A DC
Other :
6 A AC, cos φ = 1; 6 A DC, τ =0
► Protection classes
Space requirements :
IP 54
Housing :
IP 40
Terminal area :
IP 20
► Mechanical life time
10
7
switching cycles
► Electronical life time
10
5
switching cycles
► Mounting
DIN rail EN 50022 ( 35 mm )
Pay attention to housing with detachable terminal strips: if you would like to detach the terminal strips please take away the power first.
►
The ground wire has to be connected to terminal PE when an auxillary voltage used (at the terminals A1 and A2) UB~ / whit galvanic
disconnection to connect a protective conductor. By AC/DC or DC - devices is this not permitted.
All operating instructions can be found under www.automation-safety.com
Developement
Production
Special advantages
► emergency stop according to EN60204
► redundant positiv guided relay
► cyclical monitoring of the function
► housing with detachable terminal strip
(for a quick change of the devices) by the
NAG-line (without RS-NAGU.1 / RS-NAGU.2f /
RS-NAGU.1f / RS-NAGU.12)
► wireless layout
► housing of self extinguishing plastic according
to UL 94-V1
► 100% computer assisted check
Testing area
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866
Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com