Safety on bus device safe il1 / il2 / ill / il2 – NORSTAT Safety Relays User Manual
Page 34
Safety on Bus
DEVICE
SAFE IL1 / IL2 / ILL / IL2
Interbus INLINE devices ( emergency stop, safety gate controlling,
APPLICATIONS
two hand controlling, safety light curtains/barriers)
APPROVALS
CE, TÜV
CONTACTS
1 normally open safety
LED indicators for status and supply diagnostic
SPECIAL CHARACTERISTICS
diagnostic with fieldbus, integration in the inline system
LED
Channel 1, channel 2, US, UM, diagnostic
24 V DC
OPERATING VOLTAGE
POWER CONSUMPTION
ca. 1,7 W
START UP DELAY / FALLBACK TIME
-- / < 20 ms
CONTACT CAPACITY max.
4A DC, 24 V
CONTACT CAPACITY min. at 24V DC (*)
10 mA
SIMULTANEITY
ENVIRONMENTAL TEMPERATURE
-25°C to +55°C
SWITCHING CAPACITY
120 W
CONTACT SECURITY
4 A time lag
OPERATING MODE
(*) We offer all devices who have a CONTACT
CAPACITY of min. 100 mA at 24 V DC with
hard gold-plated contacts. In this way the
CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
For the operation of the device the device must be connected into a Inline
station. The voltage supply is taken over the Inlinesystem. The LED "UM"
illuminates. For a detailed description please see appropriate manuals.
Please pay attention to our circuit breaker SAFE IL2.
Sales only on inquiry
FUNCTION CIRCUIT DIAGRAM
Notice: please ask for detailed documentation.
Certifications according to
Safety relevant substance data
Depending on wiring (only max. values are given)
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866
Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com