beautypg.com

NORSTAT Safety Relays User Manual

Page 22

background image

Control devices for safety light barriers

DEVICE

SAFE L.2

Emergency stop relay

APPLICATIONS

for safety light curtains / barriers

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

3 normally open safety

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

Without opposite polarity between channels

start control choosable by a extern bridge

LED

Power, channel 1, channel 2 and restart interlock

OPERATING VOLTAGE

24 V DC (electronic fuse)

POWER CONSUMPTION

ca. 2,5 W

START UP DELAY / FALLBACK TIME

< 50 ms / < 30 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

CONTACT CAPACITY min. at 24V DC (*)

10 mA

SIMULTANEITY

Simultaneous: ca. 40ms

ENVIRONMENTAL TEMPERATURE

- 25 °C to + 55 °C

SWITCHING CAPACITY

1500 VA (resistive load)

CONTACT SECURITY

6 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied to terminals A1 and A2. The "Power" and

"restart interlock" LED´s illuminate. If this is done, a voltage of 24 V DC is be

available on the terminal S11. Terminals S12 and S22 must be wired as

shown in the application examples. To start the module, the terminals Y1

and Y2 must be bridged over normally open contact. In the following the

contacts 13-14, 23-24 and 33-34 are closed.

The LED´s of channel 1, channel 2 are illuminate and "restart interlock"

must be switched off. In series to the start-button, wired on terminals Y1 and

Y2, an external contactor can be controlled. Monitoring of the reset circuit

can be configured by external bridge between terminals BR1 an BR2.

For version with detachable clamps (screw - or cage clamps) ...

please ask our sales team!

Y1

S12 S22

Y2

Start

BWS-Empfänger

ESPE - receiver

PNP

PNP

A1 + 24 V DC

A2 0 V DC

FUNCTION CIRCUIT DIAGRAM

Überwachungslogik /

control logic

K2

K1

elektr.

Sicherung /

electr. fuse

A1

S12

(+)

BR1

S11

BR2

S22

Y1

Y2

23

13

33

K2

K1

(-)

A2

~~

=

+

-

~

~

24

14

34

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 36,16 years / high, DC: 99% / high,

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com