Device rs-nagu.1 / rs-nagu.2f – NORSTAT Safety Relays User Manual
Page 33
DEVICE
RS-NAGU.1 / RS-NAGU.2f
Muting control
APPLICATIONS
RS-NAGU.1 : CE, TÜV, UL, C-UL,
APPROVALS
RS-NAGU.2f : CE, UL, C-UL
CONTACTS
RS-NAGU.1: 3 electr. Safety semicond. outp. / RS-NAGU.2 f: 3 normally
4 muting sensors connectable
SPECIAL CHARACTERISTICS
Control of filament of external muting lamp
pushbutton
LED
Power indication, channel 1, channel 2, fault and restart interlock
OPERATING VOLTAGE
24 V DC
POWER CONSUMPTION
10 W (up to 60W including peripheral devices )
START UP DELAY / FALLBACK TIME
RS-NAGU.1 : < 6 ms - RS-NAGU.2f : < 20 ms
CONTACT CAPACITY max.
RS-NAGU.1 : 0,7 - 1,5 A
(*2)
, 24 V DC / RS-NAGU.2f : 3,5 - 6 A
(*3)
, 24 V
CONTACT CAPACITY min. at 24V DC (*)
RS-NAGU.1 : 1 mA / RS-NAGU.2f: 100 mA
(*)
SIMULTANEITY
Simultaneous of the muting sensors : 3 s
ENVIRONMENTAL TEMPERATURE
- 25°C to + 55°C
SWITCHING CAPACITY
NAGU.1 : 17 W, NAGU.2f: 84 W
CONTACT SECURITY
RS-NAGU.1 : outputs are permanently short circuit proof
RS-NAGU.2f :4 A quick acting or 3,15 A time lag
OPERATING MODE
(*) We offer all devices who have a CONTACT
CAPACITY of min. 100 mA at 24 V DC with
hard gold-plated contacts. In this way the
CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
NAGU is used for muting of safety light barriers and safety light curtains, so
that material - transport to or from a machine can be done. Applications can
be found in the automotive industry, packaging machines or at highly
automated production systems. The differentiation between human beings
and material flow is done with up to four muting sensors or two safety light
barriers. Inductive sensors or mechanical switches can also be used as
muting sensors. After connection as per application guide, the device will be
ready as soon as the power LED´s and channel 1 and channel 2 are
illuminated. If LED´s channel1/2 are blinking, a fault exists or a wrong
connection has been made. In ready condition the RS-NAGU can be started
by pushing the start key. If it cannot be started, then at least one of the
muting sensors is blocked or not connected correctly. If a muting sensor is
blocked by material supply, a muting can be initiated by actuation of the key
switch. If the light barrier is interrupted after a muting cycle, RS-NAGU can
be activated by pushing the start key after the failure has been fixed.
As soon as muting sensors 1 and 2, respectively 3 and 4 will be activated
within 3 sec., the RS-NAGU will initiate a muting cycle. Muting takes place
so long the inputs of both groups of muting sensors are in active state plus
0,25s time-delay.
RS-NAGU.1: 3 electronic safety semiconductor outputs.
RS-NAGU 2f: 3 normally open safety, 3 normally open signal outputs
(release,
and safety light barrier)
RS-NAGU (housing with detachable terminal strips) also this unit is
available
FUNCTION CIRCUIT DIAGRAM
(*) We offer all devices which have a contact capacity of min. 100 mA at 24
VDC with hard gold-plated contacts. In this way you get a contact capacity
of 4 mA.
(*2) 1,5 A permanent current (1 output) up to 4,5 A peak current
(t<1s,UV>21,6V),
1 A permanent current (2outputs), 0,7 A permanent current (3 outputs)
(*3) 6 A permanent current (1 output), 3,5 A permanent current (3 outputs)
Certifications according to
Safety relevant substance data
Depending on wiring (only max. values are given)
EN ISO 13849-1: PLe, Cat.4
MTTFd: >100 years / high, DC: 99% / high,
CCF: achieved