beautypg.com

Device rs-nagu.1 / rs-nagu.2f – NORSTAT Safety Relays User Manual

Page 33

background image

DEVICE

RS-NAGU.1 / RS-NAGU.2f

Muting control

APPLICATIONS

RS-NAGU.1 : CE, TÜV, UL, C-UL,

APPROVALS

RS-NAGU.2f : CE, UL, C-UL

CONTACTS

RS-NAGU.1: 3 electr. Safety semicond. outp. / RS-NAGU.2 f: 3 normally

4 muting sensors connectable

SPECIAL CHARACTERISTICS

Control of filament of external muting lamp

pushbutton

LED

Power indication, channel 1, channel 2, fault and restart interlock

OPERATING VOLTAGE

24 V DC

POWER CONSUMPTION

10 W (up to 60W including peripheral devices )

START UP DELAY / FALLBACK TIME

RS-NAGU.1 : < 6 ms - RS-NAGU.2f : < 20 ms

CONTACT CAPACITY max.

RS-NAGU.1 : 0,7 - 1,5 A

(*2)

, 24 V DC / RS-NAGU.2f : 3,5 - 6 A

(*3)

, 24 V

CONTACT CAPACITY min. at 24V DC (*)

RS-NAGU.1 : 1 mA / RS-NAGU.2f: 100 mA

(*)

SIMULTANEITY

Simultaneous of the muting sensors : 3 s

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

NAGU.1 : 17 W, NAGU.2f: 84 W

CONTACT SECURITY

RS-NAGU.1 : outputs are permanently short circuit proof
RS-NAGU.2f :4 A quick acting or 3,15 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

NAGU is used for muting of safety light barriers and safety light curtains, so

that material - transport to or from a machine can be done. Applications can

be found in the automotive industry, packaging machines or at highly

automated production systems. The differentiation between human beings

and material flow is done with up to four muting sensors or two safety light

barriers. Inductive sensors or mechanical switches can also be used as

muting sensors. After connection as per application guide, the device will be

ready as soon as the power LED´s and channel 1 and channel 2 are

illuminated. If LED´s channel1/2 are blinking, a fault exists or a wrong

connection has been made. In ready condition the RS-NAGU can be started

by pushing the start key. If it cannot be started, then at least one of the

muting sensors is blocked or not connected correctly. If a muting sensor is

blocked by material supply, a muting can be initiated by actuation of the key

switch. If the light barrier is interrupted after a muting cycle, RS-NAGU can

be activated by pushing the start key after the failure has been fixed.

As soon as muting sensors 1 and 2, respectively 3 and 4 will be activated

within 3 sec., the RS-NAGU will initiate a muting cycle. Muting takes place

so long the inputs of both groups of muting sensors are in active state plus

0,25s time-delay.

RS-NAGU.1: 3 electronic safety semiconductor outputs.

RS-NAGU 2f: 3 normally open safety, 3 normally open signal outputs

(release,

and safety light barrier)

RS-NAGU (housing with detachable terminal strips) also this unit is

available

FUNCTION CIRCUIT DIAGRAM

(*) We offer all devices which have a contact capacity of min. 100 mA at 24

VDC with hard gold-plated contacts. In this way you get a contact capacity

of 4 mA.

(*2) 1,5 A permanent current (1 output) up to 4,5 A peak current

(t<1s,UV>21,6V),

1 A permanent current (2outputs), 0,7 A permanent current (3 outputs)

(*3) 6 A permanent current (1 output), 3,5 A permanent current (3 outputs)

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: >100 years / high, DC: 99% / high,

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com