DEVICE

RS-NAGL / RS-NAGL.1

Emergency stop relay

APPLICATIONS

for safety light curtains / barriers

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

2 normally open safety, 1 normally auxiliary closed, 1 auxiliary n. c.

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

With (NAGL) and without (NAGL.1) opposite polarity between channels

LED

Channel 1 and channel 2

RS-NAGL / L.1: 24 V DC (without galvanic disconnection)

OPERATING VOLTAGE

RS-NAGL: 48, 110-127, 230 V AC (with galvanic

24 V AC / DC (without galvanic disconnection, but with a safety

POWER CONSUMPTION

24 V DC: 2W, 24 V AC / DC: 4,5 VA, other: 4,6 VA

START UP DELAY / FALLBACK TIME

< 150 ms / < 30 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 250 V DC

CONTACT CAPACITY min. at 24V DC (*)

10 mA

SIMULTANEITY

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

1500 VA (resistive load), 100 W

CONTACT SECURITY

6 A quick acting (normally open) or 4 A time lag (normally closed)

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied at terminals A1 and A2 in order to operate

the device. If this is done there is a voltage of 24V DC at terminal T11. T12

and T22 must be wired as shown in the application examples. Contacts 13-

14, 23-24 and 63-64 open and contact 41-42 closes. In some cases, the

transmitter from the light curtains / barrier requires a test input and is

connected to output 63-64. If 63-64 does not close, the transmitter and the

receiver will not work. This output ensures that a complete system is

created. To start the unit terminal T11 must be bridged with terminal T34

through a normally open contact (reset) or the terminal T34 must receive a

24V DC impulse (short time bridging of the connection terminals T11-T34).

If the light curtains is aligned properly and the protection zone is free, the

receiver switches. At terminal T12 there is a of voltage 24V DC and at T22

is ground. After releasing the on button or interrupting the connection

between T11 and T34 the relays K1 and K4 deenergize. Safety outputs 13-

14 and 23-24 close. Contacts 53-54 and 63-64 remain closed, contacts 41-

42 open.

*Sicherheitslichtschranke Empfänger: Relaisausgänge

*

safety light curtains receiver: relay outputs

**Anschluss Sicherheitslichtschranke Sender: Testeingang

**safety light curtains transmitter: test input

T34 T11

Start

T12 T44 T22 X1 X2 63 64

** **

*

FUNCTION CIRCUIT DIAGRAM

~

~

T44

PE

+

-

K1

K3

T1

R4

K2

K1

X1

T34

T11

Start

24

14

42

K2

K3

64

T12

X2

T22

23

13

41

63

A1 (+) A2 (-)

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 69,05 years / high, DC: 99% / high,

CCF: achieved