beautypg.com

Safety standstill monitor device safe sm (outlook) – NORSTAT Safety Relays User Manual

Page 35

background image

Safety standstill monitor

DEVICE

SAFE SM

(OUTLOOK)

Safety standstill monitor

APPLICATIONS
APPROVALS

CE, (TÜV, UL, C-UL pending)

CONTACTS

2 normally open, 1 PNP output

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

optical failure indication by LEDs

Automatic start possible

LED

Power, channel 1 IN/OUT, channel 2 IN/OUT, failure

24 V DC ( + 20 - 25 % )

OPERATING VOLTAGE

Overvoltage protection

POWER CONSUMPTION

< 3 W

START UP DELAY / FALLBACK TIME

frequency dependent

CONTACT CAPACITY max.

6 A, 250 V AC, 250 V DC

CONTACT CAPACITY min. at 24V DC (*)

5 mA

SIMULTANEITY

ENVIRONMENTAL TEMPERATURE

- 25°C to + 55°C

SWITCHING CAPACITY

1500 VA

CONTACT SECURITY

6 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

The riese SAFE SM is a safe standstill monitor. It is designed to monitor

safe speeds. Digitally switches e.g. inductive sensors or ESPD’s are

supported. SAFE SM is a two channel device. Therefore, two digitally

switches are necessary. Four safe speeds are monitored: 0.2 Hz, 0.5 Hz,

1.0 Hz and 2.0 Hz, the shifting is done via configuration wirings.

S11 S12

S34

S33

S22

S21

A1

Rückführung/ feedback

control loop

A2

+24V DC

0V DC

2x Induktionsgeber/

induction-type pulse generator

FUNCTION CIRCUIT DIAGRAM

A1

S33

S36

S12

S31

13

23

14

24

S11

S21

S32

S22

S34

S35

INPUT CIRCUIT

Mikrocontroller 1

K1

K2

POWER

OUTPUT CIRCUIT

A2

Mikrocontroller 2

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com