Device rs-nagt / rs-nagt.1 – NORSTAT Safety Relays User Manual
Page 16
DEVICE
RS-NAGT / RS-NAGT.1
Emergency stop and safety gate monitoring relay
APPLICATIONS
with time-delayed safety output
APPROVALS
CE, TÜV, UL, C-UL
CONTACTS
2 normally open safety, 1 normally open time-delayed safety output
Selectable opposite polarity between channels
SPECIAL CHARACTERISTICS
NAGT : 0,1s - 10s ; NAGT.1 : 0,3 - 30s (ask for the ordering number)
Ask for special versions
LED
Power, channel 1, channel 2 and fault
Devices has two voltages : 1 voltage fixed : 24 V DC;
OPERATING VOLTAGE
Selectable : 24, 110-127 and 230 V AC
(with galvanic disconnection/transformer)
POWER CONSUMPTION
ca. 3 VA
START UP DELAY / FALLBACK TIME
<150 ms/< 50 ms (undelayed)
CONTACT CAPACITY max.
6 A, 250 V AC, 24 V DC
CONTACT CAPACITY min. at 24V DC (*)
100 mA
(*)
SIMULTANEITY
Simultaneous protective door contacts : ca.75 ms
ENVIRONMENTAL TEMPERATURE
- 25°C to + 50°C
SWITCHING CAPACITY
1500 VA (resistive load)
CONTACT SECURITY
10 A quick acting or 6 A time lag
OPERATING MODE
(*) We offer all devices who have a CONTACT
CAPACITY of min. 100 mA at 24 V DC with
hard gold-plated contacts. In this way the
CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
A supply voltage must be applied to terminals A1 and A2 (for AC supplies)
or terminals B1 and B2 (for DC supplies). Once the supply voltage is
applied, 24V DC is available at terminal T11; power LED illuminates.
Terminals T12, K21 and K22 must be connected according to the
application example selected to meet the application requirements.
Feedback monitoring of external devices is accomplished by a connection
between terminals T34 / X1 and X2. If the application does not require
external monitoring, T34 / X1 and X2 must be bridged. To start the unit,
terminal T11 and T34 / X1 must be bridged (automatic reset) or a
momentary bridging of T11 and T34 / X1 must take place. With all of the
above in place safety contacts 13-14, 23-24 and 77-78 close. Channel 1 (K2
energized) and channel 2 (K3 energized) green LEDs illuminate to show
channel status. Fault LED illuminates when a short circuit takes place, at the
input stage or internally.
(*) Special edition with hard gold-plated contacts is also available.
Connecting the ground wire to PE - see page 22.
T11 X2
Not-Halt
E-Stop
Start
T12
K21 K22
B1(+), PE/B2(-) : 24V DC-Anschluss oder A1, A2 : AC-Anschluss
PE/B2
mit Querschlusssicherheit
with opposite polarity
between channels
T11
ohne Querschlusssicherheit
without opposite polarity
between channels
PE/B2
T11
T34/
X1
Ebene 1
Level 1
2
1
Ebene 2
Level 2
Not-Halt
E-Stop
2
2
1
1
FUNCTION CIRCUIT DIAGRAM
power on
and control
cyclic test
el
ec
tron
ic
=
fus
e
channel 1
B1(+)
+
PE/B2(-)
-
unde-
layed
K2
K4
layed
de-
~
A2
~~
~~~
A1
T1
T34/X1
T11
T12
channel 2
K3
24
14
layed
de-
K3
layed
unde-
K5
78
K5
K4
logic,
K2
K22
X2
K21
13 23
77
Certifications according to
Safety relevant substance data
Depending on wiring (only max. values are given)
EN ISO 13849-1: PLe, Cat. 4 / PLd, Cat. 3 (time delayed)
MTTFd: 57 years / high, DC: Cat. 3: 90% / medium, Cat.4: 99% / high
CCF: achieved
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866
Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com