Emergency stop and safety gate monitoring

relays

DEVICE

SAFE 2 / SAFE 2.1

Emergency stop

APPLICATIONS

and safety gate monitoring relay

APPROVALS

CE, TÜV, UL, C-UL

CONTACTS

2 normally open safety

LED indicators for status and supply diagnostic

SPECIAL CHARACTERISTICS

With (SAFE 2) and without (SAFE 2.1) start control

LED

Power, channel 1 and channel 2

OPERATING VOLTAGE

24 V AC / DC (electronic fuse)

POWER CONSUMPTION

ca. 2,5 VA / 2,5 W

START UP DELAY / FALLBACK TIME

< 50 ms / < 30 ms

CONTACT CAPACITY max.

6 A, 250 V AC, 24 V DC

CONTACT CAPACITY min. at 24V DC (*)

6 mA

SIMULTANEITY

ENVIRONMENTAL TEMPERATURE

-25°C to + 55°C

SWITCHING CAPACITY

1500 VA (resistive load)

CONTACT SECURITY

6,3 A quick acting or 4 A time lag

OPERATING MODE

(*) We offer all devices who have a CONTACT

CAPACITY of min. 100 mA at 24 V DC with

hard gold-plated contacts. In this way the

CONTACT CAPACITY of min. 100 mA is only 4 mA.

Please ask our sales team!

CONNECTION DIAGRAM

A supply voltage must be applied to terminals A1 and A2. Power LED

illuminates and 24V DC is available at terminal S11. Terminals S12 and S22

must be connected according to the application example selected to meet

the application requirements. To start the unit terminals S33 and S34 must

be bridged with a normally open contact. The unit works if you close this

contact. At this time the contacts 13-14 and 23-24 are closed. The LEDs

channel 1 and channel 2 illuminate. In series to this start button an external

contactor can be controlled.

S34 S33

S11 S12 S21 S22

Not-Halt

E-Stop

Start

FUNCTION CIRCUIT DIAGRAM

Überwachungslogik /

control logic

~

~

S21

~~

+

=

K1

A1

(+)

elektr.

Sicherung /

electronic

fuse

A2

(-)

S11

S12

14

K2

K2

24

K1

S34

S22 S33

13 23

Certifications according to

Safety relevant substance data

Depending on wiring (only max. values are given)

EN ISO 13849-1: PLe, Cat.4

MTTFd: 69 years / high, DC: 99% / high,

CCF: achieved

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com