beautypg.com

8 description of parameters – NORD Drivesystems BU0050 User Manual

Page 69

background image

2.8 Description of parameters

BU 0050 GB-3111

Subject to technical amendments

69

2.8 Description of parameters

Coil List

Via the Coil List it is possible to obtain direct access to the Bus IN/OUT bits. In order for these bits to function,
they must be parameterised in parameter P480 and P481 and the control word and setpoint must be
parameterised to the setting "Control terminals" via P509/P510.

Bus IO In Bits

Bus IO Out Bits

Coil number

Name

R/W

Coil number

Name

R/W

0000h

Bus IO In 1

R/W

0008h

Bus IO OUT 1

R

0001h

Bus IO In 2

R/W

0009h

Bus IO OUT 2

R

0002h

Bus IO In 3

R/W

000Ah

Bus IO OUT 3

R

0003h

Bus IO In 4

R/W

000Bh

Bus IO OUT 4

R

0004h

Bus IO In 5

R/W

000Ch

Bus IO OUT 5

R

0005h

Bus IO In 6

R/W

000Dh

Bus IO OUT 6

R

0006h

Bus IO In 7

R/W

000Eh

Bus IO OUT 7

R

0007h

Bus IO In 8

R/W

000Fh

Bus IO OUT 8

R

Process data

The process data is sent to the FI by means of parameter access. In order for this process data to function, the
setpoint source P509/P510 must be set to "USS".

NOTE

The parameter (P050) "Process data IN" and (P051) "Process data OUT" are executed in the
background and are not visible to the user. From a structural point of view, these are array
parameters ([-

01 … -04]). Assignment of the setpoints in parameter (P050) is carried out via

the parameters (P546 (… P548)). The return of the actual values in parameter (P051) is
assigned in parameters (P543 (… P545)).

Parameter
{factory setting}

Setting value / Description / Note

P050

[-01]

...

[-04]

Process data IN

(Process data In)

0000 ... FFFF (hex)

{ all 0 }

This parameter is an internal parameter,
which

can

neither

be

edited

nor

displayed..

The

assignment

of

the

setpoints is carried out via parameters
(P546) … (P548) (SK540E and above:
(P546[-

01]) … (P546[-03])).

[-01 ] = Control
word

Control word, source from
P509.

[-02] = Setpoint 1
[-03] = Setpoint 2
[-04] = Setpoint 3

(P546) or (P546[-01])
(P547) or (P546[-02])
(P548) or (P546[-03])

Setpoint data from main
setpoint (P510 [-01]).

P051

[-01]

...

[-04]

Process data OUT

(Process data OUT)

0000 ... FFFF (hex)

{ all 0 }

This parameter is an internal parameter,
which

can

neither

be

edited

nor

displayed.. The assignment of the actual
values is carried out via parameters
(

P543) … (P545) (SK540E and above:

(P543[-

01]) … (P543[-03])).

[-01] = Status word Status word, source from P509.

[-02] = Actual
value 1
[-03] = Actual
value 2
[-04] = Actual
value 3

(P543) or (P543[-01])
(P544) or (P543[-02])
(P545) or (P543[-03])