8 description of parameters – NORD Drivesystems BU0050 User Manual
Page 69
2.8 Description of parameters
BU 0050 GB-3111
Subject to technical amendments
69
2.8 Description of parameters
Coil List
Via the Coil List it is possible to obtain direct access to the Bus IN/OUT bits. In order for these bits to function,
they must be parameterised in parameter P480 and P481 and the control word and setpoint must be
parameterised to the setting "Control terminals" via P509/P510.
Bus IO In Bits
Bus IO Out Bits
Coil number
Name
R/W
Coil number
Name
R/W
0000h
Bus IO In 1
R/W
0008h
Bus IO OUT 1
R
0001h
Bus IO In 2
R/W
0009h
Bus IO OUT 2
R
0002h
Bus IO In 3
R/W
000Ah
Bus IO OUT 3
R
0003h
Bus IO In 4
R/W
000Bh
Bus IO OUT 4
R
0004h
Bus IO In 5
R/W
000Ch
Bus IO OUT 5
R
0005h
Bus IO In 6
R/W
000Dh
Bus IO OUT 6
R
0006h
Bus IO In 7
R/W
000Eh
Bus IO OUT 7
R
0007h
Bus IO In 8
R/W
000Fh
Bus IO OUT 8
R
Process data
The process data is sent to the FI by means of parameter access. In order for this process data to function, the
setpoint source P509/P510 must be set to "USS".
NOTE
The parameter (P050) "Process data IN" and (P051) "Process data OUT" are executed in the
background and are not visible to the user. From a structural point of view, these are array
parameters ([-
01 … -04]). Assignment of the setpoints in parameter (P050) is carried out via
the parameters (P546 (… P548)). The return of the actual values in parameter (P051) is
assigned in parameters (P543 (… P545)).
Parameter
{factory setting}
Setting value / Description / Note
P050
[-01]
...
[-04]
Process data IN
(Process data In)
0000 ... FFFF (hex)
{ all 0 }
This parameter is an internal parameter,
which
can
neither
be
edited
nor
displayed..
The
assignment
of
the
setpoints is carried out via parameters
(P546) … (P548) (SK540E and above:
(P546[-
01]) … (P546[-03])).
[-01 ] = Control
word
Control word, source from
P509.
[-02] = Setpoint 1
[-03] = Setpoint 2
[-04] = Setpoint 3
(P546) or (P546[-01])
(P547) or (P546[-02])
(P548) or (P546[-03])
Setpoint data from main
setpoint (P510 [-01]).
P051
[-01]
...
[-04]
Process data OUT
(Process data OUT)
0000 ... FFFF (hex)
{ all 0 }
This parameter is an internal parameter,
which
can
neither
be
edited
nor
displayed.. The assignment of the actual
values is carried out via parameters
(
P543) … (P545) (SK540E and above:
(P543[-
01]) … (P543[-03])).
[-01] = Status word Status word, source from P509.
[-02] = Actual
value 1
[-03] = Actual
value 2
[-04] = Actual
value 3
(P543) or (P543[-01])
(P544) or (P543[-02])
(P545) or (P543[-03])