P742
Database version
(Database version)
0 ... 9999
Displays the internal database version of the FI.
P744
Configuration level
(Configuration level)
SK 300E, SK 700E, SK 750E
0 ... 9999
This parameter displays the option modules detected by the FI.
The display with the ParameterBox is in plain text.
The possible combinations are displayed in code in the ControlBox. Both right digits indicate the
customer unit used and the two left digits indicate the special extension unit. The options vary
depending on the FI type.
Customer Unit SK CU1-
…
Special extension unit SK XU1-...
No IO
XX00
Basic IO
XX01
Standard IO
XX02
Multi IO
XX03
USS IO
XX04
CAN IO
XX05
Profibus IO
XX06
Encoder
01XX
POSICON
02XX
P744
Configuration level
(Configuration level)
SK 5xxE
0000 ... FFFF (hex)
This parameter displays the design status integrated in the FI. Display is in hexadecimal code
(SimpleBox, ControlBox, Bus system).
The display is in plain text when the ParameterBox is used.
SK 500E … 515E
= 0000
SK 520E
= 0101
SK 530E … 535E
= 0201
SK 540E … 545E
= 0301
P745
Module version
(Module version)
SK 300E, SK 5xxE
0.0 ... 3276.7
Design status (software version) of the technology unit (SK TU2/3-xxx), but only when a separate
processor is present, therefore not for SK TU2/3-CTR.
Have this data available if you have a technical query.
P745
...[-01]
…
... [-03]
Module version
(Module version)
SK 700E, SK 750E
0.0 ... 3276.7
Software version of the installed module
[-01] Technology unit
[-02] Customer Unit