Reading the acceleration time parameter
The acceleration time parameter (USS No. = 102
dec
/ 66
hex
) in parameter set 2 of a frequency inverter with the
USS address 3, is to be read out. No process data is transferred.
Procedure:
Set address (Address 03)
Generate parameter label (PKE 10 66)
Select parameter set 2 (IND = 01)
Send telegram
Check response telegram (PWE = 3E8)
Details:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
STX
LGE
ADR
PKE
PKE
IND
IND
PWE
PWE
STW
STW
SW1
SW1
BCC
02
0C
03
10
66
00
01
00
00
00
00
00
00
7A
The response telegram of the slave contains the required parameter value in internal standardisation and
could be as follows:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
STX
LGE
ADR
PKE
PKE
IND
IND
PWE
PWE
ZSW
ZSW
IW1
IW1
BCC
02
0C
03
10
66
00
01
03
E8
0B
31
20
00
A8
The value sent in PWE2 is C8
HEX
corresponding to 1000
DEC
, with a resolution of 0.01 seconds, this
corresponds to an acceleration time of 1000 * 0.01 = 10 seconds
10 / 0.01 = 1000 (3E8
hex
)