2 ppo types – NORD Drivesystems BU0050 User Manual
Page 27
1.5 USS - Data transfer
BU 0050 GB-3111
Subject to technical amendments
27
1.5.2
PPO types
For cyclic data traffic, the Parameter- Process data Object (PPO) with which the process data (PZD) and
parameters (PKW) are transferred from the master to the frequency inverter is defined. The frequency
inverter can process PPO types 1, 2, 3 or 4.
Type
Task
PPO1
extended parameter data telegram with 32 bit parameter values and process data
PPO2
Telegram with extended process data (main and two auxiliary setpoint values) and 32 bit parameter value
PPO3
Process data telegram with main setpoint value without parameter data
PPO4
extended process data telegram with main and auxiliary setpoint values without parameter data
PPO3 and PPO4 are purely process data objects for applications which do not require parameter
processing.
Abbreviations used:
PPO
Parameter Process data Object
STW
Control word
PKW
Parameter identifier Value
ZSW
Status word
PZD
Process data
SW1..3
Setpoints 1-3
PKE
Parameter identifier
IW1..3
Actual values 1-3
IND
Index
PWE
Parameter Value
Note::
An SPS can normally only consistently transfer double words by means of I/O memory access.
For longer data formats (PKW channel always / PZD data with PPO2 or PPO4) system functions
(e.g. SFC 14, consistent data reading / SFC15, consistent data writing) must be used.
NOTE
Because of the protocol specification, for PPO types 2 and 4 6 words must be reserved for
the address area of the process data (PZD). The two last words are not used for the process
data telegrams and are therefore merely reserve areas.