FUTEK IPM500 (D500) Digital Display User Manual
Page 38
0 1 1 8
1 0 0 16
1 0 1 32
1 1 0 64
1 1 1 128
0 Alarm1 Band Deviation
1 Alarm1 Hysteresis
0 Alarm2 Band Deviation
1 Alarm2 Hysteresis
2B
Alarm Cnfg1
Bit 7 6 5 4 3 2 1 0
0 0 0 0 Al1 Hi Active, Al2 Hi Active
0 0 0 1 Al1 Lo Active, Al2 Hi Active
0 0 1 0 Al1 Disabled, Al2 Hi Active
0 1 0 0 Al1 Hi Active, Al2 Lo Active
0 1 0 1 Al1 Lo Active, Al2 Lo Active
0 1 1 0 Al1 Disabled, Al2 Lo Active
1 0 0 0 Al1 Hi Active, Al2 Disabled
1 0 0 1 Al1 Lo Active, Al2 Disabled
1 0 1 0 Al1 Disabled, Al2 Disabled
0 0 Al1 Non-Latch, Al2 Non-Latch
0 1 Al1 Latch, Al2 Non-Latch
1 0 Al1 Non-Latch, Al2 Latch
1 1 Al1 Latch, Al2 Latch
0 0 Relay1 On when Al1 active, Relay2 On when Al2 active
0 1 Relay1 Off when Al1 active, Relay2 On when Al2 active
1 0 Relay1 On when Al1 active, Relay2 Off when Al2 active
1 1 Relay1 Off when Al1 active, Relay2 Off when Al2 active
10.2 COUNTER / TIMER 2-BYTE RAM DATA TABLE
Hex MS Hex LS
Name
Hex Range
Dec Range
40
3A
38
3F
39
37
Pulses
Timeout
Gatetime
0000 EA5F
0000 4E1F
0000 4E1F
0 59999 Positive magnitude (Units = 1)
0 19999 Positive magnitude (Units = 0.01 sec)
0 19999 Positive magnitude (Units = 0.01 sec)
10.3 COUNTER / TIMER 3-BYTE RAM DATA TABLE
Values stored as 3-byte 2s complement
Hex MS
Hex Mid
Hex LS
Name
B0
AA
9E
AD
A4
9B
AF
A9
9D
AC
A3
9A
AE
A8
9C
AB
A2
99
Deviation2 (values always+) (Hysteresis2)
Offset2
Setpoint2
Deviation1 (values always+) (Hysteresis1)
Offset 1
Setpoint1
Values stored as sign (MS bit) + magnitude (all other bits), fixed DP = 6
Hex MS
Hex Mid
Hex LS
Name
A7
A1
A6
A0
A5
9F
Scale2
Scale1
10.4 COUNTER / TIMER NON-VOLATILE MEMORY ADDRESSES (2 bytes / address)
Sign + Magnitude
XXXX XXXX XXXX XXXX XXXX XXXX XXXX
S Magnitude
Sign + DP + Magnitude XXXX XXXX XXXX XXXX XXXX XXXX XXXX
S DP Magnitude
S = Sign
Sign = 1 for negative
DP = 1 for DDDDDD.
DP = 6 for D.DDDDD
Hex Address
MS Byte
LS Byte
Stored As
74
73
72
71
70
6F
6E
6D
6C
6B
6A
32
31
30
2F
2E
Deviation4 Byte 3
Deviation4 Byte 1
Deviation3 Byte 2
Setpoint4 Byte 3
Setpoint4 Byte 1
Setpoint3 Byte 2
Alarm Confg4
Version
T Stop
R Show
R Stop
Serial Confg4
Total A Byte 6
Total A Byte 4
Total A Byte 2
Total B Byte 6
Deviaion4 Byte 2
Deviation3 Byte 3
Deviation3 Byte 1
Setpoint4 Byte 2
Setpoint3 Byte 3
Setpoint3 Byte 1
Alarm Confg3
M Type
T Start
R Skip
R Start
Modbus Address
Total A Byte 5
Total A Byte 3
Total A Byte 1
Total B Byte 5
Magnitude
Magnitude
Magnitude
2s Complement
2s Complement
2s Complement
Bits
Magnitude
Bytes
Magnitude
Bytes
Magnitude
Magnitude
Magnitude
Magnitude
Magnitude
38