FUTEK IPM500 (D500) Digital Display User Manual
Page 17

Meter #
Meter SER 2
Digit 5(6)
Serial Comm
Address Code
Meter #
Meter SER 2
Digit 5(6)
Serial Comm
Address Code
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
0.
1.
2.
3.
4.
5.
6.
7.
8.
9.
A.
B.
C.
D.
E.
F.
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
CHARS 3 & 4 - COMMANDS AND SUBCOMMANDS
The examples below use a default address of 1 following the *. Substitute the desired
address from the above table of Serial Comm Address Codes. All command sequences shown
must terminate with
COMMUNICATIONS MODE
Continuous mode *1A0
Command mode *1A1
REQUEST DPM VALUES
Get reading** *1B1
Peak reading *1B2
Valley reading *1B3
** The meter transmits the value or values selected in Ser 3.
REQUEST SCALE METER VALUES
Get reading** *1B1
Peak only *1B2
Net only *1B3
Gross only *1B4
Valley only *1B5
** The meter transmits the value or values selected in Ser 3.
REQUEST COUNTER VALUES
All active items *1B0
Item 1 *1B1
Item 2 *1B2
Item 3 *1B3
Peak *1B4
Displayed item *1B5
Valley only *1B6
All active items + Peak + Valley *1B7
RESET FUNCTIONS, DPM & SCALE METER
Cold reset *1C0 Reads NVMEM into RAM locations after RAM is zeroed.
Latched alarms reset *1C2
Peak value reset *1C3
Remote display reset *1C4
External Input B true *1C5
External Input B false *1C6
External Input A true *1C7
External Input A false *1C8
Valley reset *1C9
Tare function *1CA
Tare reset *1CB
RESET FUNCTIONS, COUNTER / TIMER
Cold reset *1C0 Reads NVMEM into RAM locations after RAM zeroed.
Function reset *1C1 Resets all total values and/or peak value.
Latched alarms reset *1C2
Peak value reset *1C3
Remote display reset
*1C4 Resets Item 3 to zero if not Arith or Batch.
Removes Alarm View or Peak View if on.
External Input B true *1C5
External Input B false *1C6
External Input A true *1C7
External Input A false *1C8
Valley value reset *1CA
8.3 READING AND WRITING TO RAM AND NONVOLATILE MEMORY
CHARACTERS 1, 2
The Recognition character and Meter Address Code are the same as shown in previous table.
CHARACTER 3
Command character:
17