FUTEK IPM500 (D500) Digital Display User Manual
Page 17

Meter #
Meter SER 2
Digit 5(6)
Serial Comm
Address Code
Meter #
Meter SER 2
Digit 5(6)
Serial Comm
Address Code
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
16 
17 
18
19
20 
21 
22
23
24
25
26
27
28
29
30
31
0.
1.
2.
3.
4.
5.
6.
7.
8.
9.
A.
B.
C.
D.
E.
F.
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
CHARS 3 & 4 - COMMANDS AND SUBCOMMANDS 
The examples below use a default address of 1 following the *. Substitute the desired 
address from the above table of Serial Comm Address Codes. All command sequences shown 
must terminate with 
COMMUNICATIONS MODE 
Continuous mode *1A0 
Command mode *1A1 
REQUEST DPM VALUES 
Get reading** *1B1 
Peak reading *1B2
Valley reading *1B3 
** The meter transmits the value or values selected in Ser 3. 
REQUEST SCALE METER VALUES 
Get reading** *1B1 
Peak only *1B2
Net only *1B3
Gross only *1B4
Valley only *1B5 
** The meter transmits the value or values selected in Ser 3. 
REQUEST COUNTER VALUES 
All active items *1B0 
Item 1 *1B1
Item 2 *1B2
Item 3 *1B3
Peak *1B4
Displayed item *1B5
Valley only *1B6 
All active items + Peak + Valley *1B7 
RESET FUNCTIONS, DPM & SCALE METER 
Cold reset *1C0 Reads NVMEM into RAM locations after RAM is zeroed. 
Latched alarms reset *1C2
Peak value reset *1C3 
Remote display reset *1C4 
External Input B true *1C5
External Input B false *1C6 
External Input A true *1C7 
External Input A false *1C8
Valley reset *1C9
Tare function *1CA 
Tare reset *1CB 
RESET FUNCTIONS, COUNTER / TIMER 
Cold reset *1C0 Reads NVMEM into RAM locations after RAM zeroed. 
Function reset *1C1 Resets all total values and/or peak value.
Latched alarms reset *1C2
Peak value reset *1C3
Remote display reset
*1C4 Resets Item 3 to zero if not Arith or Batch.
Removes Alarm View or Peak View if on.
External Input B true *1C5
External Input B false *1C6
External Input A true *1C7
External Input A false *1C8 
Valley value reset *1CA 
8.3 READING AND WRITING TO RAM AND NONVOLATILE MEMORY
CHARACTERS 1, 2 
The Recognition character and Meter Address Code are the same as shown in previous table. 
CHARACTER 3
Command character: 
17