System reset options -39 – Asante Technologies 6200 User Manual
Page 86

System Reset Options
Page 5-39
4
Select one of the options in the above screen 
to select the required baud rate and confirm 
it by typing 
y.
5
Type
a to select the Destination Bank.
6
Use any serial communications software like 
Procomm Plus, HyperTerminal, ZTerm, etc., 
to download the image file. Follow the 
instruction manual of the serial communica-
tions software for file transfer instructions.
∆
Note: The terminal on which serial communica-
tions software is running must have the same baud 
rate as the Switch console baud rate. The connec-
tion between the terminal and the switch Console 
port is RS232C straight-through cable.
7
Type
d to download to the selected destina-
tion bank or
b to download and reset.
8
Type
q to return to the previous menu after
performing a successful download.
∆
Note: The baud rate default for Console manage-
ment is 9600 bps. If you select a baud rate for the 
console port, other than 9600 bps, the screen will 
display garbage data until the connected terminal 
is set to the same baud rate as the console. 
System Reset Options
The System Reset Options Menu allows you to reset the 
IntraSwitch by performing a “warm” reboot. It also allows you 
to schedule a reset up to 24 hours in advance. 
To reset the IntraSwitch, type
r in the Configuration Menu. A
screen similar to Figure 5-16 appears.
6216M Book Page 39 Wednesday, January 27, 1999 5:26 PM