Ruggedcable system, Suspension wire – In-Situ Level TROLL 400/500/700/700H Operators Manual User Manual
Page 13

1-800-446-7488
13
www.in-situ.com
RuggedCable System
General
RuggedCable System
Operating temp. range
-25° to 80° C (-13° to 176° F)
Jacket options
TPU (thermoplastic polyurethane)
Tefzel (ETFE fluoropolymer; generic equivalent to Teflon)
Vent options
Non-vented (absolute)
Vented (gauged) with desiccant (used to mitigate moisture/humidity)
Conductors
6 conductors, 24 AWG, polypropylene insulation
Cable diameter
TPU: 6.7 mm (0.265 in.)
Tefzel: 6.35 mm (0.25 in.)
Connector diameter
18. 5 mm (0.73 in.)
Weight
Non-vented, TPU: 16 kg/300 m (35.6 lbs/1,000 ft)
Non-vented, Tefzel: 14 kg/300 m (32 lbs/1,000 ft)
Vented, TPU: 14 kg/300 m (32 lbs/1,000 ft)
Vented, Tefzel: 14 kg/300 m (32 lbs/1,000 ft)
Minimum bend radius
2X cable diameter (13.5 mm; 0.54 in.)
Break strength
127 kg (280 lbs)
Maximum cable length
1,219 m (4,000 ft) for RS485
Desiccant pack
(required for vented
systems)
Large and extra large desiccant packs available with titanium, ABS, or stripped-and-tinned
termination.
Warranty
2 years
Specifications are subject to change without notice.
Suspension Wire
General
Suspension Wire
Material
304 stainless steel, 7 x 7 strand
Coating
15 mil polyester elastomer insulation
Weight
0.28 kg / 30 m (0.60 lb / 100 ft)
Break strength
122 kg (270 lb) with proper clip tightening
Specifications are subject to change without notice.