beautypg.com

GW Instek GDM-8246 Programming Manual User Manual

Page 21

background image

GDM-8246 MULTIMETER

PROGRAMMER MANUAL

⎯ 40 ⎯

:CALCulation: SDBM:REFerence

Examples:

:CALCulation:SDBM:REFerence? might return 0600 in DC voltage
function.

:CALCulation: SDBM:REFerence 600 sets 600 ohm DC voltage at the
reference standard value.

Please refer to the unit for every range shown as Table 6-4:

Table 6-4:

Selectable Reference Impedance in ohms:

2 93

250

1000

4 110

300

1200

8 124

500

8000

16 125 600

50 135 800

75 150 900

:CALCulation:HOLD

Function:

Returns or sets the Hold and Auto-hold mode on or off.

Syntax:

:CALCulation:HOLD?

:CALCulation:HOLD

can be o(off), 1(hold),or 2(auto-hold).

Examples:

:CALCulation:HOLD? might return 2 in the Auto-hold mode.

GDM-8246 MULTIMETER

PROGRAMMER MANUAL

⎯ 41 ⎯

:CALCulation:HOLD 1 sets the Hold mode.

STATus:OPERation:CONDition?

(query only)

Function:
Return the contents of the OPERation register. The DMM, however, do
not use the OPERation register to report any conditions.

Syntax:

STATus:OPERation:CONDition?

Returns:

Examples:

STATus:OPERation:CONDition? returns 0.

STATus:OPERation:ENABle

Function:
Set or query the enable mask that allows the masked conditions in the
event register to be reported in the summary bit. If a bit is 1 (true) in the
enable register and its associated event bit changes to 1 (true), the
associated summary bit will change to 1 (true). Even though this is a
16-bit register, only 15 bits (bit 0 through bit 14) are used. Bit 15 always
reads 0.

Syntax

STATus:OPERation:ENABle

STATus:OPERation:ENABle?

is an integer from 0 to 32767.

Returns