GW Instek GPI-700A Series Programming Manual User Manual
Page 24
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 45 ⎯
Return:
Examples:
:DCWStanding:TTIMe 5.0 set the DCW test time to 5 sec.
:DCWStanding:TTIMe? return 005.0 if the DCW test time setting is 5 sec.
:IRESistance:VOLTage
Function:
Set or query the IR test voltage.
Syntax:
:IRESistancce:VOLTage
:IRESistancce:VOLTage?
Return:
Examples:
:IRESistancce:VOLTage 100 set the IR test voltage to 100V.
:IRESistancce:VOLTage? return 0100 if the IR test voltage setting is 100V.
:IRESistance:RMINimum
Function:
Set or query the IR test minimum resistance.
Syntax:
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 46 ⎯
:IRESistance:RMINimum
:IRESistance:RMINimum?
Return:
Examples:
:IResistance:RMINimum 100 set the IR test minimum resistance to 100MΩ.
:IResistance:RMINimum? return 0100 the IR test minimum resistance setting is
100MΩ.
:IRESistance:RMAXimum
Function:
Set or query the IR test maximum resistance.
Syntax:
:IRESistance:RMAXimum
:IRESistance:RMAXimum?
Return:
Examples:
:IRESistance:RMAXimum 100 set the IR test maximum resistance to 100MΩ.
:IRESistance:RMAXimum? return 0100 the IR test maximum resistance setting
is 100MΩ.