Examples:
:UTILity: FREQuency 50 set the ACW CAC frequency to 50Hz
:UTILity: FREQuency? return 50 if the ACW CAC frequency setting is 50Hz.
:UTILity:ARC:CURRent
Function:
Set or query the ARC current
Syntax:
:UTILity:ARC:CURRent
:UTILity:ARC:CURRent?
Return:
Examples:
:UTILity:ARC:CURRent 2.00 set the ARC current to 2.00mA.
:UTILity:ARC:CURRent? return 02.00 if the ARC current setting is 2.00mA.
:UTILity:ARC:MODe
Function:
Set or query the ARC test state
(0:disable, 1:Enable & Stop, 2:Enable & Continue)
Syntax:
:FUNCtion:TEST:STATe
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 32 ⎯
:FUNCtion:TEST:STATe?
Return:
Examples:
:UTILity:ARC:MODe 0 set the AEC test state to disable.
:UTILity:ARC:MODe? return 0 if the ARC mode setting is disable.
:UTILity:TEST:MODe
Function:
Set or query the test mode (0: From Step 1, 1: From the present step )
Syntax:
:UTILity:TEST:MODe
:UTILity:TEST:MODe?
Return:
0 | 1
Examples:
:UTILity:TEST:MODe 0 set the test mode from step 1.