GW Instek GPI-700A Series Programming Manual User Manual
Page 18
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 33 ⎯
:UTILity:IRTest:MODe
Function:
Set or query the IR test mode (0: Stop on Fail, 1: Stop on Pass, 2: TIMER )
Syntax:
:UTILity:IRTest:MODe
:UTILity:IRTest:MODe?
Return:
Examples:
:UTILity:IRTest:MODe 0 set the IR test mode stop on fail.
:UTILity:IRTest:MODe? return 0 if the IR test mode setting is STOP on Fail.
:UTILity:GBZero:TEST
Function:
Start the GB zero check.
Syntax:
:UTILity:GBZero:TEST
Return:
Examples:
:UTILity:GBZero:TEST Start the GB zero check.
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 34 ⎯
:UTILity:GBZero:STATe
Function:
The query from return 1 if the GB zero check is OK and 0 if the GB zero check is
fail.
Syntax:
:UTILity:GBZero:STATe?
Return:
0|1
Examples:
:UTILity:GBZero:STATe? Return 1 if the GB zero check is OK.
:ACContinue:VOLTage
Function:
Set or query the CAC test voltage.
Syntax:
:ACContinue:VOLTage
:ACContinue:VOLTage?
Return:
Examples:
:ACContinue:VOLTage 1.000 set the CAC test voltage to 1.000kV.
:ACContinue:VOLTage? return 1.000 if the CAC test voltage setting is 1.000kV.