Edwards Signaling 102 DeviceNet User Manual
Page 5

P/N 3100125 ISSUE 3
PAGE 5
For Units Configured with 3 Light Modules
BYTE
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
0
DON'T
DON'T
DON'T
DON'T
DON'T
LMP 3
LMP 2
LMP 1
CARE
CARE
CARE
CARE
CARE
1 = ON
1 = ON
1 = ON
0 = OFF
0 = OFF
0 = OFF
1
0
0
1
DON'T
DON'T
LMP 3
LMP 2
LMP 1
45
CARE
CARE
1 = FLSH
1 = FLSH
1 = FLSH
FPM
0 = STDY
0 = STDY
0 = STDY
1
0
1
0
DON'T
DON'T
LMP 3
LMP 2
LMP 1
60
CARE
CARE
1 = FLSH
1 = FLSH
1 = FLSH
FPM
0 = STDY
0 = STDY
0 = STDY
1
1
DON'T
DON'T
DON'T
DON'T
LMP 3
LMP 2
LMP 1
80
CARE
CARE
CARE
CARE
1 = FLSH
1 = FLSH
1 = FLSH
FPM
0 = STDY
0 = STDY
0 = STDY
1
0
0
0
DON'T
DON'T
LMP 3
LMP 2
LMP 1
80 FPM
80 FPM
80 FPM
CARE
CARE
1 = FLSH
1 = FLSH
1 = FLSH
DEFLT
DEFLT
DEFLT
0 = STDY
0 = STDY
0 = STDY
2
DON'T
DON'T
DON'T
DON'T
Sounder
Tone
Tone
Tone
CARE
CARE
CARE
CARE
1 = ON
MSB
LSB
0 = OFF
For Units Configured with 2 Light Modules
BYTE
BIT7
BIT6
BIT5
BIT4
BIT3
BIT2
BIT1
BIT0
0
DON'T
DON'T
DON'T
DON'T
DON'T
DON'T
LMP 2
LMP 1
CARE
CARE
CARE
CARE
CARE
CARE
1 = ON
1 = ON
0 = OFF
0 = OFF
1
0
0
1
DON'T
DON'T
DON'T
LMP 2
LMP 1
45
CARE
CARE
CARE
1 = FLSH
1 = FLSH
FPM
0 = STDY
0 = STDY
1
0
1
0
DON'T
DON'T
DON'T
LMP 2
LMP 1
60
CARE
CARE
CARE
1 = FLSH
1 = FLSH
FPM
0 = STDY
0 = STDY
1
1
DON'T
DON'T
DON'T
DON'T
DON'T
LMP 2
LMP 1
80
CARE
CARE
CARE
CARE
CARE
1 = FLSH
1 = FLSH
FPM
0 = STDY
0 = STDY
1
0
0
0
DON'T
DON'T
DON'T
LMP 2
LMP 1
80 FPM
80 FPM
80 FPM
CARE
CARE
CARE
1 = FLSH
1 = FLSH
DEFLT
DEFLT
DEFLT
0 = STDY
0 = STDY
2
DON'T
DON'T
DON'T
DON'T
Sounder
Tone
Tone
Tone
CARE
CARE
CARE
CARE
1 = ON
MSB
LSB
0 = OFF