beautypg.com

Temperature, Instability indication – DeFelsko PosiTector 6000 v.4.0 User Manual

Page 26

background image

26

Temperature

Operating range: +32

°

to +120

°

F

(0 to +50

°

C).

The 6000 compensates automatically for
temperature. Allow a few minutes for the
Gage to reach ambient temperature
before measuring.

Discard the first measurement taken in a
notably different temperature condition.
When measuring surfaces much hotter or
colder than ambient, allow 1 second off
the surface between measurements.

TIP: Ferrous substrates with extreme

temperatures between -150

°

F and

+450

°

F (-100

°

C and +230

°

C) can be

measured with the PosiPen

. It is

ideally suited for measuring on small,
hot or hard-to-reach surfaces. Contact
your dealer.

NOTE:

The gage will not perform

temperature compensation unless the
probe is lifted from the surface by at
least 6 inches for at least 10 seconds
after a reading.

NOTE:

If readings on thick coatings

appear to be inconsistent, remove the
gage from the surface by at least 6
inches for at least 10 seconds to allow
the gage to periodically compensate its
calibration

.

Instability Indication

A high, fast, beeping sound emitted
during measuring indicates the Gage
requires more time than usual to
determine a coating thickness
measurement.

This occurs if the probe is touching a very
hot or cold surface, or if the probe is not
being held steady.